Synthes rfna surgical technique

Apply the insertion handle to the medial side of t

The FIBULINK Syndesmosis Repair System provides a repair solution for ankle fractures of the syndesmosis. It is compatible with all DePuy Synthes distal fibula plates and is packaged in sterile, single-use packaging. This system features: Stainless steel or titanium implants. Tibia Screw.6 Surgical Technique fiflCONFIDENCE SPINA CEMENT SYSTEM ™ Surgical Technique Needle Placement The trajectory by which the needle is inserted varies depending on the vertebra to be treated. Most commonly a transpedicular or extrapedicular approach is performed. A uni-pedicular or bi-pedicular approach may be used at the operator's discretion.Surgical technique Product information Expert Tibial Nail 2 AO Principles of Internal Fixation 4 Indications 5 Cases 6 ... Expert Tibial Nail Technique Guide Synthes 1. T h i s p a t i e n t h a s s o m e S y n t h e s ® lo ck i n g s c r e w s w i t hexalo b ul a r in t e r n a l d r i v e a c c o r d i n g t o E N I S O 1 0 6 6 4 Stardrive® T40 0 mm 5 mm 10 mm 15 mm 2 …

Did you know?

Preservation of blood supply. Preservation of the blood supply to soft tissues and bone by gentle reduction techniques and careful handling. have become the guidelines for internal fixation.1,2. Anatomic reduction. Fracture reduction and fixation to restore anatomical relationships. Early, active mobilization.Screw Removal Set Surgical Technique DePuy Synthes 5 To remove cannulated screws The following table shows instruments that are required for the removal of broken cannulated screws. The instruments shown in parentheses are suitable if the break is in the shaft. Screw Removal Set. Instruments for removing DePuy Synthes screws. 309.510 …compaction broach-only surgical technique, the CORAIL Total Hip System has demonstrated long-term stem survivorship of 96.3% at 25 years.2 Over time, additions have been made to the original CORAIL Hip System to provide additional options for orthopaedic surgeons treating today’s patients, including:Femoral shaft fracture: Fixation with Depuy-Synthes Expert retrograde/antegrade femoral nail (RAFN) Surgical Technique - OrthOracle. VIEW: The retrograde/antegrade …The small shielded calcar reamer (940080007) is to be used for sizes from 8 to 12. The large shielded calcar reamer (L94010) is to be used for sizes 13 and above. Note 4.1 Ensure all soft tissue is clear before performing calcar reaming. CORAIL Upgrade Kit Surgical Technique DePuy Synthes Joint Reconstruction . Open the catalog to page 11Synthes Rfna Technique Guide Jiang Zhi: Love Letters Jiang Zhi 2016-05-26 Jiang Zhi's flowers 'die' before our eyes -set aflame, they are on the brink of death, not yet devoured. ... The advent of microvascular surgery, skeletal analysis, computerized surgical planning, personalized implant creation, and comprehensive radiographic analysis have ...8 DePuy Synthes Variable Angle LCP Two-Column Volar Distal Radius Plate 2.4 Surgical Technique Use of funnel-shaped end of VA-LCP Drill Sleeve Use of freehand VA-LCP Drill Sleeve (03.111.004) Screw Insertion Techniques VA-LCP Drill Sleeve (03.110.000) VA-LCP Drill Sleeve, freehand (03.111.004), for off-axis drilling Funnel-shaped end for off-Introduction PFNA - System Overview 2 Surgical Technique Preoperative Planning 14 Option: PFNA Augmentation 45 Correction of Insertion Depth of PFNA Blade 76 . ... PFNA small, length 200 mm PFNA long, length 300-420 mm, with 20 mm increments, bending PFNA. With Augmentation Option. Technique Guide Synthes 3 .3.5 mm Intrapelvic Acetabular System • Surgical Technique 5 Surgical Technique 1. Retractor Positioning Retract soft tissue using appropriate retractors. The naming of the retractor indicates the bony structure each retractor is intended to expose. Take care to avoid excessive or prolonged tension and pressure on nearbySURGICAL TECHNIQUE Preoperative planning makes it possible to: 1. Identify the lower level of the extended trochanteric osteotomy (ETO) required to fully remove the failed primary implant and any cement; this involves taking measurements in relation to several reference points (the top of the greater trochanter and the lesser trochanter, the femoral condyle, and any osteosynthesis material ...36 Surgical Technique • 2.7 mm Variable Angle LCP®Clavicle Hook Plate System. Product Information Implants. 2.7 mm Variable Angle Locking Screws*. 02.211.010- 2.7 mm Variable Angle Locking Screw 02.211.040 S elf-tapping, StarDrive recess, Stainless steel Available in 10 mm-40 mm lengths, in 2 mm increments 04.211.010- 2.7 mm Variable ...Used together, the ATTUNE™ Knee and Patient-Specific Alignment Techniques are designed to preserve the soft tissue envelope and reduce the requirement for soft tissue releases, helping to restore stable knee motion and improve patient satisfaction after total knee arthroplasty (TKA). Get in Touch With a Sales Consultant.16 Synthes PFNA Surgical Technique Surgical Technique 1 Determination of PFNA entry point and guide wire inser-tion In AP view, the PFNA entry point is usually on the tip or slightly lateralto the tip of the greater trochanter in the 6° curved extension of the medullary cavity, as the ML angle of the PFNA is 6°.About This Product. The FRN-ADVANCED System is intended for treatment of fractures in adults and adolescents in which the growth plates have fused. Intended applications include: Subtrochanteric fractures. Ipsilateral neck/shaft fractures. Femoral shaft fractures. Impending pathologic fractures. Malunions and nonunions.4.5 mm Cannulated Screws Surgical Technique DePuy Synthes 3 AO Principles In 1958, the AO formulated four basic principles, which 1 4 2 3 4_Priciples_03.pdf 1 05.07.12 12:08 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which

Kindly say, the Synthes Rfna Technique Guide is universally compatible with any devices to read Jiang Zhi: Love Letters Jiang Zhi 2016-05-26 Jiang Zhi's flowers 'die' before our eyes -set ... computerized surgical planning, personalized implant creation, and comprehensive radiographic analysis have given rise to new principles, techniques and.(RFNA). Type A Type B Type C . 4 Surgical Technique fiVariable Angle LCP Periprosthetic Proximal Femur Plating System 3.5/4.5/5.0 Indications and Contraindications Indications The DePuy Synthes VA-LCP PPFx Proximal Femur Plates and Proximal Femur Hook Plates 3.5/4.5/5.0 are indicated for the treatment of periprosthetic fractures and fractures …Mixing, approximately 70 seconds Mix the contents of the rotary pouch using the rotary mixer. (70 revolutions). Preparation time, 3 minutes Three minutes maximum at room temperature (18°-23 °C). Transfer the mixed Norian Drillable paste into the delivery syringe and transfer the delivery syringe into the sterile field.The Dusky Arion slug provided scientists with unlikely inspiration for a glue that sticks to wet surfaces. Learn more at HowStuffWorks. Advertisement Have you ever gotten out of th...pull traction at 30° angle over triangle for reduction. Reaming. ream 1.5mm above size of final nail. Nail Insertion. insert nail over guidewire. Interlocking Screws. targeting guide to place distal interlocking screws first. check femoral neck, get perfect circles of proximal interlocking screws and insert.

Variable Angle Locking Patella Plating System. The VA Locking Anterior Patella Plate 2.7 is designed to address different fracture patterns as per approved indication. The surgical technique guide includes two sections: Complex Fractures - 3-hole and 6-hole plates are recommended. Simple Fractures - Core, 3-hole, and 6-hole plates may be ...3.5 mm LCP® Olecranon Plates Surgical Technique DePuy Synthes 13 2 Fixation with 3.5 mm locking screws Instruments 310.288 2.8 mm Drill Bit, quick coupling 312.648 2.8 mm Threaded Drill Guide 314.115 StarDrive Screwdriver, T15 314.116 StarDrive Screwdriver Shaft, T15 319.01 Depth Gauge 511.770* Torque Limiting Attachment, 1.5 Nm or 511.773 ……

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. compaction broach-only surgical technique, the C. Possible cause: DESCRIPTION. The Femoral Neck System (FNS) is a solution for femoral neck fractures whe.

The DePuy Synthes VA-LCP PPFx Proximal Femur Plating System 3.5/4.5/5.0 provides two main plate options and an additional attachment plate for the treatment of periprosthetic hip fractures: VA-LCP PPFx Proximal Femur Plate 3.5/4.5/5.0. Designed with a focus on Type B fractures. Features an anatomically shaped plate head and shaft.DESCRIPTION. The Femoral Neck System (FNS) is a solution for femoral neck fractures where the growth plates have fused or cannot be crossed. Designed for improved …

Surgical techniques: how I do it? The Reamer/Irrigator/Aspirator (RIA) system Injury. 2009 Nov;40 ... (Synthes, Inc., West Chester, PA) was developed as a simultaneous reaming and aspiration system to reduce the intramedullary pressure, heat generation, operating time, and systemic effects of reaming. It was designed with an …36 Surgical Technique • 2.7 mm Variable Angle LCP®Clavicle Hook Plate System. Product Information Implants. 2.7 mm Variable Angle Locking Screws*. 02.211.010– 2.7 mm Variable Angle Locking Screw 02.211.040 S elf-tapping, StarDrive recess, Stainless steel Available in 10 mm–40 mm lengths, in 2 mm increments 04.211.010– 2.7 mm Variable ...The Synthes TFNA is an evolution of the Synthes PFNA. It has many features in common with most proximal femoral nails for fragility fractures, the proximal end has a larger diameter than standard nails to increase fit in osteoporotic bone, distally the end of the short nail is tapered and there is just a single locking bolt to reduce the stress ...

Table of Contents SS ® Fracture System fi Surgica Femoral Neck System (FNS) Surgical Technique DePuy Synthes 14 3. Determine length Instrument 03.168.003 Direct Measuring Device for 3.2 mm Guide Wires Slide the direct …Synthes Rfna Technique Guide Jiang Zhi: Love Letters Jiang Zhi 2016-05-26 Jiang Zhi's flowers 'die' before our eyes -set aflame, they are on the brink of death, ... computerized surgical planning, personalized implant creation, and comprehensive radiographic analysis have given rise to new principles, techniques and possibilities, which are ... Care and Maintenance of Synthes Instruments", Article NoIn our relatively small sample of 8 patients tre 4 DePuy Synthes Expert Lateral Femoral Nail Surgical Technique AO PRINCIPLES In 1958, the AO formulated four basic principles, which have become the guidelines for internal fixation1,2. 1 Müller ME, M Allgöwer, R Schneider, H Willenegger. Manual of Internal Fixation. 3rd ed. Berlin Heidelberg New York: Springer. 1991. 🏥 This video guides you through the step-b 37mm 28mm 19mm 9.5mm 27mm 63mm 47.5mm 13.5mm 18.5mm SPEC SHEETS www.jnjmedicaldevices.com © DePuy Synthes 2021. All rights reserved. 164479-210113 02/21Pizza dough, for the most part, is comprised of only a few basic ingredients. But there’s no doubt that some crusts are just way better than others. So what’s the difference betwee... Want to learn the photography techniques everyonspanning external fixator system (ie. Stryker Hoffman 3, ZimmThe RFN-ADVANCED™ System is a retrograde femoral nailing The R/AFN is a cannulated intramedullary nailing system for the treatment of fractures of the distal femur and/or diaphyseal fractures in which a retrograde approach is indicated. The R/AFN also enables fixation of fractures of the femoral shaft with an antegrade approach through the piriformis fossa. The R/AFN has a universal design for the right or left femur with an anatomic bend (1.5 meter ...2 DePuy Synthes Joint Reconstruction CORAIL Upgrade Kit Surgical Technique Surgical Technique Step 1: Pre-Operative Planning The CORAIL Hip System provides pre-operative templates at three different magnifications (100%, 115% and 120%). The templates are placed over the AP and lateral radiographs to help determine the implant size in compaction broach-only surgical techniqu The DePuy Synthes Variable Angle Locking Patella Plating System is indicated for the fixation and stabilization of patellar fractures in normal and osteopenic bone in skeletally mature patients. Contraindications. No contraindication specific to these devices. 2.4/2.7 mm Variable Angle Locking Lateral Rim Patella Plates • Surgical Technique 5 Recommended technique. A complete surgical technique is provid[The Synthes Multiloc nails come in a short and lo2 DePuy Synthes Surgical Technique Femoral Ne ing the technique described in the LCP Instructions for Use. Insert the fixation bolt in hole A of the insertion guide. Place the insertion guide on the three-point locking mechanism of the plate. Hole A LCP Distal Femur Plates with LISS Instrumentation • Surgical Technique 96 DePuySynthes OPAL™ Spacer System Surgical Technique 1. Determine implant size Option A: Insert and rotate technique Instruments 03.803.011– Trial Implant OPAL, 03.803.015 size 11 mm–15 mm Precaution: The insert and rotate technique can only be used for sizes 10 mm–15 mm. For all other sizes, use the impact technique.